Tripp Lite SU10000RT3U2TF 10000VA UPS Smart Online Rack/Tower PureSine 10kVA 200-240V Hardwired
See all 20 items in product family

Tripp Lite SU10000RT3U2TF 10000VA UPS Smart Online Rack/Tower PureSine 10kVA 200-240V Hardwired

Item #: WBB246307

Sold By: globalindustrial.com

Out of stock, please check back soon. Estimated lead times do not include weekends or holidays. Transit time is determined by shipping method and destination. Orders requiring credit information might take additional time.

0 reviews | Write a review

Price: $ 7,527.00

with FREE shipping today! (within the contiguous US)

Product Information
Customer Review
Product Q&A
10,000 VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 10 rack spaces (3U power module, 3U battery pack and two 2U step-down transformers). Maximum installed rack depth of 32.5 in. Expandable battery runtime with optional external battery packs. Full-time sine wave 208V and 120V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Standard 3-wire 208V hardwire input connection; NEMA L6-30R, L6-20R and 5-15/20R output receptacles. Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs offer at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. LED/LCD display panel easily rotates for better viewing in rackmount or tower configurations. LCD panel with scroll buttons offers detailed diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included; 2POSTRMKITWM two post rackmount hardware accessories available. Field-replaceable, hot-swappable power module and external battery 2-Year Limited Warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.

  • 10,000 VA on-line, double-conversion UPS system (high voltage input/high AND low voltage output)
  • Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment
  • Installs in only 10 rack spaces (3U power module, 3U battery pack, 2 x 2U step-down transformers) with a maximum installed depth of 32.5 inches
  • Offers 4 min. runtime at full load (10,000VA/8000W) and 10 min. at half load (5000VA/4000W). Runtime is expandable with any number of optional external battery packs
  • Full-time sine wave 208V and simultaneous 120v +/-2% output
  • Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output
  • Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V
  • Standard 3-wire 208V hardwire input connection
  • 2 NEMA L6-30R, 4 L6-20R and 24 5-15/20R output receptacles
  • Detailed LCD panel with scroll buttons offers detailed diagnostic test
  • Network-grade AC surge and noise suppression
  • Zero transfer time between AC and battery operation
  • Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port, and contact closure port for unattended shudown, remote control and monitoring of UPS system and power data
  • Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling
  • Emergency Power Off (EPO) interface
  • Front panel LEDs offer at-a-glance confirmaline power status, battery power status, AC-to-DC & DC-to-AC conversion, bypass mode and output power status.


Product Specifications

    • WATTS8000
    • POWER PROTECTIONUPS Battery Backup
    • VOLTAGE1000
    • DIMENSIONS (HxWxD)5.25 x 17.5 x 25
    • BATTERY RECHARGE RATE2-8 hours to 90 Percent
    • LED 6Power
    • LED 5Output AC
    • OUTLET QTY24 5-15/20R Outlets, 4 L6-20R Outlets, 2 L6-30R Outlets
    • BRANDTripp Lite
    • FULL LOAD RUN TIME12 Minutes
    • LED 4Inverter
    • LED 3Charger
    • LED 2Bypass
    • LED 1Battery Operation
    • MAX. INPUT200v - 46.7A / 208v - 44.9A / 220v - 42.4A / 230v - 40.6A / 240v - 38.9A
    • SWITCH 1Power
    • MANUFACTURERS PART NUMBERSU10000RT3U2TF
    • SWITCH 22 Front Panel Mounted Switches
    • FREQUENCY50/60 Hz
    • ALARMSYes
    • WEIGHT136.5
    • INPUT PLUG TYPEHardwire