Tripp Lite SU10000RT3U 10000VA UPS Smart Online Rack/Twr PureSine 10kVA 200-240V 6 Outlet
See all 20 items in product family

Tripp Lite SU10000RT3U 10000VA UPS Smart Online Rack/Twr PureSine 10kVA 200-240V 6 Outlet

Item #: WBB246306

Sold By: globalindustrial.com

Usually ships in 5 to 8 days Estimated lead times do not include weekends or holidays. Transit time is determined by shipping method and destination. Orders requiring credit information might take additional time.

0 reviews | Write a review

Price: $ 6,208.00

with FREE shipping today! (within the contiguous US)

Product Information
Customer Review
Product Q&A
10,000VA (10kVA) on-line, double-conversion UPS system for critical server, network and telecommunications equipment. Installs in only 6 rack spaces (3U power module and 3U battery pack); maximum installed rack depth of 32.5 in. Expandable battery runtime with optional external battery packs. Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output. Actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without consuming battery power during brownouts to 156V and overvoltages to 276V. Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs. Standard 3-wire 208V hardwire input connection; NEMA L6-30R and L6-20R output receptacles. Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without disrupting power to connected equipment. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support communications via RS-232, contact-closure port and optional SNMPWEBCARD slot. Supports detailed monitoring of equipment load levels, self-test data and utility power conditions via network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Front panel LEDs provide at-a-glance confirmation of line power status, battery power status, AC-to-DC conversion, DC-to-AC conversion, bypass mode and output power status. LED/LCD display panel rotates for better viewing in rackmount or tower configurations. Detailed LCD panel with scroll buttons provides detailed diagnostic test information at startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage and battery charge level. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories and 2-9USTAND tower kit included; 2POSTRMKITWM 2-post rackmount hardware accessories available. Field-replaceable, hot-swappable power module and external battery packs. Attractive all-black color scheme. 2-Year Limited Warranty; extended warranty and service contracts available. $250,000 connected equipment insurance

  • 10,000VA (10kVA) on-line, double-conversion UPS system (high-voltage input/high-voltage output)
  • Detachable input-output PDU module with manual bypass switch enables hot-swap UPS replacement without powering off connected equipment
  • Installs in only 6 rack spaces (3U power module/3U battery pack) with a maximum installed depth of 32.5 in.
  • Offers 4 min. runtime at full load (10,000VA/8000W) and 10 min. at half load (5000VA/4000W). Runtime is expandable with any number of optional external battery packs
  • Full-time sine wave 200, 208, 220, 230, or 240V +/-2% output (user selectable)
  • Actively converts raw incoming AC power to DC, then re-converts output to completely regulated, filtered AC output
  • Operates continuously without using battery power during brownouts to 156V and overvoltages to 276V
  • Standard 3-wire 208V hardwire input connection
  • 4 x NEMA L6-20R and 2 x NEMA L6-30R output receptacles
  • Detailed LCD panel with scroll buttons provides detailed diagnostic test information on startup and during self tests, plus real-time data on input and output voltage, frequency (Hz), load percentage, battery charge level and more
  • Network-grade AC surge and noise suppression
  • Zero transfer time between AC and battery operation
  • Includes slot for internal SNMP/web card, plus DB9 enhanced serial monitoring port, and contact closure port for unattended shudown, remote control and monitoring of UPS system and power data
  • Supports detailed monitoring of equipment load levels, self-test data and mains power conditions via network interfaces. PowerAlert monitoring software and complete cabling
  • Emergency Power Off (EPO) interface


Product Specifications

    • WATTS8000
    • POWER PROTECTIONUPS Battery Backup
    • VOLTAGE1000
    • DIMENSIONS (HxWxD)39.75 x 31.5 x 23
    • BATTERY RECHARGE RATE2-8 hours to 90 Percent
    • LED 6Power
    • LED 5Output AC
    • OUTLET QTY4 L6-20R Outlets, 2 L6-30R Outlets
    • BRANDTripp Lite
    • FULL LOAD RUN TIME12 Minutes
    • LED 4Inverter
    • LED 3Charger
    • LED 2Bypass
    • LED 1Battery Operation
    • MAX. INPUT200v - 46.7A / 208v - 44.9A / 220v - 42.4A / 230v - 40.6A / 240v - 38.9A
    • SWITCH 1Power
    • MANUFACTURERS PART NUMBERSU10000RT3U
    • SWITCH 22 Front Panel Mounted Switches
    • FREQUENCY50/60 Hz
    • ALARMSYes
    • WEIGHT55
    • INPUT PLUG TYPEHardwire

Avg. Customer Rating: (0 customer reviews)