Tripp Lite SU3000RTXL3U 3000VA UPS Smart Online Rack/Tower PureSine 3kVA 9 Outlet
See all 20 items in product family

Tripp Lite SU3000RTXL3U 3000VA UPS Smart Online Rack/Tower PureSine 3kVA 9 Outlet

Item #: WBB246374

Sold By: globalindustrial.com

Usually ships in 5 to 8 days Estimated lead times do not include weekends or holidays. Transit time is determined by shipping method and destination. Orders requiring credit information might take additional time.

0 reviews | Write a review

Price: $ 1,948.00

with FREE shipping today! (within the contiguous US)

Product Information
Customer Review
Product Q&A
3000VA on-line, double-conversion UPS system for critical server, network and telecommunications equipment. 3U rackmount form factor with an installed depth of 26 inches. Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT-3U (multi-pack compatible) external battery packs. Full time sine wave 110 or 120V output with +/-2% voltage regulation. Online, double-conversion Uninterruptible Power Supply (UPS) actively converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Operates continuously without using battery power during brownouts to 65V and overvoltages to 150V. Highly efficient operation in optional economy mode saves BTU heat output and energy costs. NEMA L5-30P input plug. NEMA 5-15, NEMA 5-15/20R and NEMA L5-30R output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. Built-in DB9 port offers both enhanced RS-232 enabled monitoring data, plus contact closure monitoring ability. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 network interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. Integrated two-bank PDU switching supports load shedding and remote reboot of connected equipment. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for viewing in rackmount or tower configurations. Dataline surge suppression for dialup, DSL or network Ethernet connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto-bypass mode. 4-post rackmount accessories included; 2-9USTAND tower kit and 2POSTRMKITWM 2-post rackmount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-Year Limited Warranty and $250,000 connected equipment insurance; extended warranty and service contracts available.

  • SmartOnline high performance UPS system is ideal for critical voice, data, medical and industrial network applications
  • True on-line, double-conversion UPS provides perfectly regulated sine wave output within 2% of 110/120V (user selectable) under all usage conditions
  • Maintains continuous operation through blackouts, voltage fluctuations and surges with zero transfer time
  • Highly efficient operation in optional economy mode setting, saving BTU heat output and energy costs
  • Removes harmonic distortion, fast electrical impulses, frequency variations and other hard to solve power problems not addressed by other UPS types
  • Corrects line voltage conditions as low as 65V and as high as 150V back to selectable 110/120V (+/-2%) values
  • Standard internal battery set offers 14 minutes runtime at half load (1200W) and 5 minutes at full load (2400W)
  • Expandable battery runtime with optional BP72V15-2U (limit 1) and BP72V28RT-3U (no limit) external battery packs
  • Compact rackmount form factor installs using only 3 rack spaces (3U) with a maximum installed depth of 26 inches
  • Ships with all mounting accessories for 4 post rackmount installation
  • Optional 2POSTRMKITWM enables 2 post rackmount installation (not wallmount compatible)
  • Optional 2-9USTAND accessory enables small-footprint upright tower placement
  • Fault tolerant auto-bypass maintains continuous utility output to connected equipment, even in cases where the UPS suffers internal failure and requires maintenance
  • Network interfacrt simultaneous communications via built-in USB, DB9 serial / contact-closure and SNMPWEBCARD slot


Product Specifications

    • WATTS2400
    • POWER PROTECTION--
    • VOLTAGE3000
    • DIMENSIONS (HxWxD)5.25 x 17.5 x 19.8
    • BATTERY RECHARGE RATE2-4 hours to 90 Percent
    • LED 5Overload
    • OUTLET QTY4 5-15R Outlets, 4 5-15/20R Outlets, 1 L5-30R Outlet
    • BRANDTripp Lite
    • FULL LOAD RUN TIME5 Minutes
    • LED 4Online
    • LED 3On battery
    • LED 2Bypass
    • LED 1Battery Low
    • MAX. INPUT22A / 2844 watts max
    • SWITCH 1Main Power Switch
    • MANUFACTURERS PART NUMBERSU3000RTXL3U
    • FREQUENCY50/60 Hz
    • ALARMSBattery Back up Operation
    • WEIGHT112.4
    • INPUT PLUG TYPENEMA L5-30P