Browse Fire Protection (1,069 Items) |
|
 |
Edwards Signaling, E-FSC502R, Conventional Fire Alarm Control Panels, 5 Zone, 120V, Red |
| |
|
 |
|
 |
|
 |
|
|
|
Edwards Signaling, E-FSC502R, Conventional Fire Alarm Control Panels, 5 Zone, 120V, Red
|
|
Sold by: globalindustrial.com
|
Availability: Usually ships in 3 to 6 days
Stock No: WBB790349
|
|
|
|
Price: $546.00
|
|
|
|
 |
Product Information |
 |
|
 |
Product Q&A |
 |
|
|
 |
Edwards Signaling, E-FSC502R, Conventional Fire Alarm Control Panels, 5 Zone, 120V, Red
Features:
- The E-FSC502 fire alarm panels consists of 5 zone conventional fire alarm control panels, an integrated DACT/Dialer, serial annunciator modules, and serial remote relay modules. All of these components are microprocessor-controlled.
- E-FSC Series family is ideal for both new and retrofit installations alike.
- E-FSC Series incorporates features designed to simplify installation, operation and maintenance.
- Front panel programming, one person walk testing, and selectable IDC and NAC types.
- E-FSC Series panels are powerful enough to meet the demands of today s installations while leaving plenty of room to grow in the future.
- E-FSC502 panels support Class A operation by combining pairs of on-board IDCs or NACs to provide the necessary Class A circuits. For example, the E-FSC502 comes factory set to support five Class B IDCs and two NACs.
- Field-configured to provide two Class A IDCs, no Class B IDCs, and one Class A NACs or any other combination of circuits that fall within the circuit-pairing parameters.
- IDC or NAC pairs convertible to single Class A circuits
- Combination Waterflow and Supervisory IDCs
- NACs programmable by zone and individually selectable for Genesis, continuous, temporal outputs, or coded
- Front panel programmable simplifies installation and servicing PC programmable with optional DACT installed
- Genesis option allows precision synchronization and audible silence over two wires without additional modules
- On-board relays for Alarm, Supervisory and Trouble
- Optional serial bus relay modules are programmable for common or zone activation
- Optional serial bus remote annunciator family
- One person walk-test (audible or silent)
- Optional City Tie and Reverse Polarity Modules
- Trim ring available for semi-flush mounting
- Optional fully integrated DACT/Dialer for PC programming
- Supports Edwards ED2M, SC and 2400 series detectors and ESL 400, 500 and 700 series detectors
|
| Product Specifications |
| DESCRIPTION |
Fire Alarm Control Panels |
| MANUFACTURERS PART NUMBER |
E-FSC502R |
| APPROVALS |
UL, ULC, CSFM |
| POWER SUPPLY |
4.25A |
| NAC VOLTAGE RATING |
24Vfwr, regulated |
| TO BE USED WITH |
E-FSC |
| OPERATING VOLTAGE |
24V |
| AC INPUT |
120Vac |
| OPERATING TEMPERATURE |
42 - 120°F |
| OPERATING HUMIDITY |
93% |
| INPUT ZONES |
5 |
| BRAND |
Edwards Signaling™ |
| MAX NAC CURRENT |
3.5A |
|
|
|
|
 |
|
|